Parameters in the file para.ini: advanced configuration
SAGEM RT3000
91
Datei 8115AD002-Total.doc
Datei gespeichert
24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04,
18:17
Status Release
Descriptions:
Fax only on Port B (no voice)
[Can be configured by DTMF, SMS, FTP] In case of any trouble with the
recognition of outgoing fax sent from the fax machine connected to the
SAGEM RT3000, you can configure that each call initiated on the
Fax/Modem/Phone
will be handled like a fax call. Therefore set this
parameter:
FAX_PORT_B=YES.
Timeout for local fax in seconds
[Can be configured by SMS, FTP] You can configure in what time (in
seconds) the fax machine connected to the SAGEM RT3000 must react to an
incoming fax call to accept the call. If the timeout expires, the SAGEM RT3000
will not receive the incoming fax.
FAX_ACCEPT_TIMEOUT=20
Maximum retries for local fax
[Can be configured by SMS, FTP] If the SAGEM RT3000 has stored a part of
a received fax because the connection to the local fax has been interrupted,
the SAGEM RT3000 will try to resend the stored part of the fax document to
the local fax machine automatically.
With the parameter FAX_RETRY_MAX=<> you can configure the number of
retries.
With the parameter FAX_RETRY_DELAY=<> you can configure the delay
between two retries.
Success fax after completed MOC
[Can be configured by DTMF, SMS, FTP] When you send a fax by your local
fax machine via the SAGEM RT3000 the SAGEM RT3000 can return a report,
whenever the transmission to the remote station is successful. Parameter:
FAX_SUCCESS_REPORT= YES
Disconnect on AC power fail
[Can be configured by SMS, FTP] If during a fax transmission the mains
power gets a blackout and the battery is low, the fax transmission may fail
because the SAGEM RT3000 shuts down immediately. In this case there is a
small risk that both parties do not recognise that the transmission failed
although they did not get an error report. To avoid this wrong behaviour, you
can set that a transmission is immediately disconnected, if mains power fails.
Parameter:
AC_DOWN_DISCONNECT=YES,