Parameters in the file para.ini: advanced configuration
SAGEM RT3000
107
Datei 8115AD002-Total.doc
Datei gespeichert
24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04,
18:17
Status Release
; POWER_REPORT: YES or NO, default is YES
POWER_REPORT=NO
POWER_REPORT_NR=
SMS_PORT=C
; SMS_CONFIG: YES or NO, default is YES
SMS_CONFIG=YES
; SMS_CLIP: YES or NO, default is NO
SMS_CLIP=YES
; TEST_SMS: only used to test configuration-sms
TEST_SMS=222
[CALL_MUX]
VOICE_ALERT=A
; can be A, B, AB or BA - default A
DATA_ALERT=B
; C = PC-PORT; can bee A, B, C, AB, etc
FAX_ALERT=B
; can be ABC, default is B
FAX_PORT_B=NO
; if YES, Port B generates only fax calls
DATA_PORT_B=NO
; YES makes port B Data only (FAX_PORT_B=YES overrides)
FAX_ACCEPT_TIMEOUT=20
; time in seconds, to wait for hookoff of local fax
FAX_RETRY_MAX=3
; count of retries to deliver local fax
FAX_RETRY_DELAY=30
; time in seconds, to wait for next retry
INTERNATIONAL=00
FAX_SUCCESS_REPORT=NO
EMERGENCY_1=112
EMERGENCY_2=112
EMERGENCY_3=112
; prefix to force data/fax call (do NOT use DTMF config sequences)
DATA_PREFIX=***
FAX_PREFIX=###
[FAX]
IDENT=RT3000
;FAXAPP_DEBUG=COM
;T30_DEBUG=COM