Configuration methods
SAGEM RT3000
83
Datei 8115AD002-Total.doc
Datei gespeichert
24.04.04 13:23 von EDV/ORGA
Druckzeit 24.04.04,
18:17
Status Release
!
If SMS_CONFIG =YES is set, the telephone numbers of the stations that are
allowed to send a configuration SMS have to be set in the section
[DEVICE_ACCESS] as parameter SERVICE_CLIP_0 to SERVICE_CLIP_4.
!
The SIMPIN and the parameter SMS_CONFIG can not be modified by a SMS.
15.3
Configuration by FTP (Local and Remote)
The configuration of the SAGEM RT3000 is written in the file
para.ini
that is stored in
the memory of the device. You can edit this file with a text editor (capable of writing
plain text).
To do this do the following steps:
To edit the
configuration file
para.ini:
1. Download by FTP
2. Edit
3. Upload by FTP
1. Download the file para.ini from the SAGEM RT3000 to your
computer using a FTP program. (FTP programs are available
in the Internet as freeware.)
You can download the
para.ini
file
•
from a local PC that is connected to the SAGEM RT3000
via its RS-232 port or its USB port
•
from a remote PC that can establish a PPP connection via
CSD (Circuit Switched Data) connection to the SAGEM
RT3000.
You can configure up to 5 remote stations that are allowed
to download and upload files (see
Settings for the
configuration access via SMS and FTP
, page 85).
To establish the connection to the SAGEM RT3000 with a
Windows computer you have to establish and start
1. the DIAL UP NETWORK connection to the SAGEM
RT3000 (see connection data below) and
2. establish the FTP connection to the SAGEM RT3000 (see
connection data below).
Download from:
Local PC:
Dial Up Network:
Dial string:
*98#
User name:
service
Password:
service
Use the modem driver that
belongs to the SAGEM
RT3000: Rt3000
User name and password are
stored in the
para.ini
file.
Default settings are:
[SERVICE_IF]
USER=service
PASSWORD=service