Change during operation: N = impossible,
Y* = possible (enabled by using ), Y= possible (enabled by using
)
-33-
FUNC
DATA
5 Selecting Function
5-1
Function Selection List
Table 5-1-1 Table
of
Function Selection List
Func-
tion
code
No
.
Name
Setting range
Unit
Min.
unit
Factory
setting
Change
during
operation
User
setting
F00
Data protection
0: Data change enabled,
1: Data protected
-
-
0
N
F01
Frequency command
0:Key operation (
,
key)
1:Voltage input (terminal [12])
(0 to +10Vdc, 0 to +5Vdc)
2:Current input (terminal[C1])
(4 to 20mAdc)
3:Voltage input + current input
(terminals[12]+[C1])
4:Analog (VR built in drive)
-
-
4
N
F02
Operation method
0: Keypad operation
1: Terminal operation (STOP key active)
2: Terminal operation (STOP key inactive)
3: Terminal operation (STOP key active)
with
special
software
4: Terminal operation (STOP key inactive)
with
special
software
-
-
0
N
F03
Maximum output fre-
quency
50 to 120Hz
Hz
1
60
N
F04
Base frequency
25 to 120Hz
Hz
1
60
N
F05
0
F06
-
Data cannot be changed.
-
-
0
-
F07
Acceleration time
0.0 to 60.0s
0.01 second is set when 0.0 is specified.
s
0.1
6.0
Y
F08
Deceleration time
0.1 to 60.0s
s
0.1
6.0
Y
F09
Torque boost
0,1
:
Variable torque
characteristic
2 to 31: Constant torque
characteristic
-
1
13
Y
F: Fundamental functions