Change during operation: N = impossible,
Y* = possible (enabled by using ), Y= possible (enabled by using
)
-35-
FUNC
DATA
Func-
tion
code
No.
Name
Setting range
Unit
Min.
unit
Factory
setting
Change
during
operation
User
setting
E01
X1 terminal function
-
-
0
N
E02
X2 terminal function
-
-
2
N
E03
X3 terminal function
Use the code values listed below to se-
lect [
X1],
[
X2]
and [
X3]
terminal func-
tions.
-
-
3
N
0: Multistep frequency 1 (SS1)
1: Multistep frequency 2 (SS2)
2: Coast-to-stop command (BX)
3: Alarm reset (RST)
4: External alarm (THR)
5: Write enable command for keypad
(WE-KP)
6: PID control cancel (Hz/PID)
7: Link operation selection (LE)
Func-
tion
code
No.
Name
Setting range
Unit
Min.
unit
Factory
setting
Change
during
operation
User
setting
C01
Jump frequency 1
0 to 120Hz
Hz
1
0
Y
C02
2
1
0
Y
C03
3
1
0
Y
C04
(Hysteresis)
0 to 30Hz
Hz
1
3
Y
C05
Multistep frequency 1
0.0 to 120Hz
Hz
0.1
0.0
Y
C06
2
0.1
0.0
Y
C07
3
0.1
0.0
Y
E: Extension Terminal Functions
C: Control Functions of Frequency