MorphoAccess® SIGMA Family Administrator Guide
MorphoAccess® Terminal Administration Menu
2017_2000025464-v03
This document and the information therein are the property of Morpho. They must not
be copied or communicated to a third party without the prior authorization of Morpho
165
July 17
Figure 143:
Configuring Parameters in “SDC Mode”
The administrator can select the following parameters when the SDC Mode is enabled.
4.
Press on Door Unlock Time field to set the duration (in Seconds only) for which the
door should be unlocked after access is granted. E.g. if 25 seconds is the Door Unlock
Time, then the door will be unlocked for 25 seconds and after that the door will be
locked automatically
5.
Press on Door Held Open Duration, to set the duration (in Seconds only) within which
the door must be closed. Once Door Unlock Time has elapsed and the door has not
been closed; the terminal will start counting the Door Held Open Duration. If user has
not closed the door within this duration, an auto-alert “Door Held Open Too Long” will
be generated on terminal
6.
Select the Exit Mode as ‘None’, ‘Push button – Manual’ or ‘Push button – Electric’
7.
The administrator needs to set the Egress Time Out when Exit Mode is in ‘Push Button-
Manual’ mode. Within the Egress Time Out period, the door will remain open and on
timeout it will lock automatically. An Egress Time Out should be configured between
the range of 1 to 300 seconds
8.
The administrator can Select Default Relay State as ‘On’ or ‘Off’ which translates to
‘powered’ or ‘unpowered’.
a.
“OFF” indicates that by default the internal relay will be unpowered and on
access granted the internal relay state will change to high (it will be powered).
b.
“ON” indicates that by default the internal relay will be powered and on access
granted the internal relay state will change to low (it will be powered off).