![SAF CFIP PhoeniX C Technical Description Download Page 94](http://html.mh-extra.com/html/saf/cfip-phoenix-c/cfip-phoenix-c_technical-description_796097094.webp)
94
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
Figure 70: Write confirmation
When the configuration is properly saved, it is possible to write actual configuration also into optional
memories (W1-W3). This operation saves actual settings as alternative configuration for subsequent
quick restoration of such configuration scheme with relevant RUN W0 – RUN W3 button click
(Figure 71).
Button RETURN TO PREVIOUS PAGE in the right bottom corner of GUI page helps to quick return to the
previous active page.
ATTENTION:
Make sure that all modes work properly and remote access to IDU is still possible
before start-up memory saving. The automatic restore function can not return to the status before
start-up memory saving then.
Figure 71: Write and Run commands
Configuration backup and export
It is recommended to make a backup of complete IDU configuration for an eventual system fault. In
order to guarantee quick system repair or units replacement this backup configuration should be
stored on reliable medium.
The access to backup process is available from GUI page
„Maintenance / Files”
(Figure 72).
Backup procedure
A description of recommended steps for the backup configuration follows:
–
Login over web browser with ADMIN rights.
–
Save currently running configuration with WRITE button, which is available on each GUI page.
Then the start-up memory will
contain the actual configuration.
–
Select Save Config checkbox in section FILES and press GENERATE.
–
Press right mouse button on fwconf_xxx_xxx.afw file, and select destination for this file and save
it.