![SAF CFIP PhoeniX C Technical Description Download Page 65](http://html.mh-extra.com/html/saf/cfip-phoenix-c/cfip-phoenix-c_technical-description_796097065.webp)
65
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
-
off –
This item (mode) disables aggregation function. The function in this mode is similar to
function of design MULTI but with just three channels over air.
–
TX Aggreg Mode
– This drop-down menu sets the specific Tx aggregation modes. The possible
modes are:
-
auto
– TX data stream is automatically divided into two links according to momentary
available capacity of each link.
-
master only
– Aggregation is disabled in this mode. TX data stream is manually directed to
master link only.
-
slave only
– Aggregation is disabled in this mode. TX data stream is manually directed to
slave link only.
–
TX Aggreg Status –
This box shows actual TX status which is especially important for auto
aggregation mode. In this mode the aggregation block automatically decides what direction will
be used for Tx data transmission:
-
aggregate –
Data are transferred over both links (normal mode).
-
master only –
Data are transferred over master link (slave link is down or in some trouble
or mode is manually set to master only).
-
slave only –
Data are transferred over slave link (master link is down or in some trouble or
mode is manually set to slave only).
–
RX Aggreg Mode
– This box displays status of receiving part in an aggregation block:
-
ok –
Receiving block operates properly, both traffic directions are aligned.
-
alignment drops –
Incorrect order of packet is detected at receiving side, this status
indicates abnormal packet delay at master or slave link.
-
packet discards –
This status indicates packet losses at master or slave link.
–
Packet MUX Sync
– This box displays actual Packet MUX synchronization at master and slave
unit.
–
Fiber Optic Sync
– This parameter shows actual Fiber Optic interconnection status between
master and slave unit.
–
Device Status
– This value shows alarm status of relevant unit.
Basic Link Info
It is recommended to fill-in the table with complete link identification. This will be helpful for next
system description. Such configuration is accessible from WEB GUI page
„General / Info”