![SAF CFIP PhoeniX C Technical Description Download Page 126](http://html.mh-extra.com/html/saf/cfip-phoenix-c/cfip-phoenix-c_technical-description_796097126.webp)
126
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
Figure 114: Example 8 – 1+1 FD Protection scheme
IDU1
IDU2
IDU3
IDU4
General | Protection
Configuration
master/FD
slave/FD
master/FD
slave/FD
IP | Address
Local IP
10.10.10.10/24
10.10.10.11/24
10.10.10.9/24
10.10.10.8/24
Remote IP
10.10.10.9
10.10.10.8
10.10.10.10
10.10.10.11
Protection IP
10.10.10.11
10.10.10.10
10.10.10.8
10.10.10.9
Gateway IP
10.10.10.1
10.10.10.1
10.10.10.1
10.10.10.1
Radio | Parameters
Tx Frequency
14580 MHz
14680 MHz
15000 MHz
15100MHz
Tx Power
3 dBm
3 dBm
3 dBm
3 dBm
Ports | Parameters
Speed Allocation [Mbps]
ETH1 = 140
ETH2 = 1
ETH3 = 34
ETH1 = 140
ETH2 = 1
ETH3 = 34
ETH1 = 140
ETH2 = 1
ETH3 = 34
ETH1 = 140
ETH2 = 1
ETH3 = 34
Ports | ETH VLAN
Port Mode
basic = all ports
basic = all ports
basic = all ports
basic = all ports
Port Groups
1 = lan2/3, mng, wanB
2 = lan1, wanA
1 = lan2/3, mng, wanB
2 = lan1, wanA
1 = lan2/3, mng, wanB
2 = lan1, wanA
1 = lan2/3, mng, wanB
2 = lan1, wanA
The protection mode „OFF” is activated by default on both IDUs after change to PROTECTED design. In
this mode just port LAN 3 (and USB B) can be used for management connection, ODU transmitter is
automatically muted. It prevents any Ethernet loops or radio interferences during configuration
process.