LED indicators on the CFIP-ASI-EXT – system status
–
STATUS
– indication of the LOCAL EMM status
-
Lights – status OK (card enabled, proper communication with IDU)
-
Flashes – status WARNING (card is not enabled in the system or no communication with
IDU or configuration was not finished yet)
-
No light – status ERROR (a firmware is not loaded into Extension module HW)
–
POWER
– indication that Extension module is under power (green LED)
-
Lights – power ON
-
No light – power OFF
LED indicators on the CFIP-ASI-EXT – ports status
–
SFP 1/2 LINK
– indication of presented signal at SFP port
-
Flashes – signal detected and synchronized, valid communication with IDU
-
No light – no correct signal detected
–
ASI STATUS
– indication of ASI status; depends on mode settings of appropriate ASI port (1-4):
–
Port in Tx Mode
–
Blink – ASI signal presented, sending data
–
No light – no data (IDLE status)
–
Port in Rx Mode
–
Lights – signal detected but in IDLE or
nosync
mode
–
Blink – incoming ASI signal
–
No light – no ingress signal detected