![SAF CFIP PhoeniX C Technical Description Download Page 100](http://html.mh-extra.com/html/saf/cfip-phoenix-c/cfip-phoenix-c_technical-description_796097100.webp)
100
CFIP PhoeniX C Series TDM/IP Split Mount System Technical Description and Configuration Guide
•
Rev. 1.0
•
© SAF Tehnika JSC 2013
Figure 75: Example 1
–
In-Band management separated by means of VLAN
IDU1 (provider side)
IDU2 (customer side)
Maintenance | Advanced
Design
single
single
IP | Address
Local IP
10.10.10.10/24
10.10.10.9/24
Remote IP
10.10.10.9
10.10.10.10
Gateway IP
10.10.10.1
10.10.10.1
Ports | Parameters
Speed Allocation [Mbps]
ETH1 = 362
ETH1 = 362
Ports | ETH VLAN
Port Mode
hybrid = lan1/2, wanA/B
access = lan3, mng
hybrid = lan1/2, wanA/B
access = lan3, mng
Port Groups
1 = all ports
1 = all ports
VTU Setting
add 100 group1 off TTUUTT
add 100 group1 off DDUUTD
Design SINGLE must by selected as the first step in configuration process on both IDUs.