EN
45
EN
5.41
5.35
5.36
5.19
5.27
5.23
5.31
5.22
5.30
5.42
5.44
5.47
5.45
5.48
5.43
5.26
0,5
0,5
0,5
0,5
See parameter 5.18
See parameter 5.18
See parameter 5.41
00:00
00:00
00:00
00:00
23:59
23:59
23:59
23:59
OFF
M-Su
M-F
Sa-Su
M ….. Su
See parameter 5.18
FS
FS
FS
FS
OFF
Par 1,1
Par 1,1
Bar
Bar
4
4
4
4
Not used
Not used
OFF
00:00
00:00
00:00
00:00
OFF
Not used
Bar
Bar
Bar
Bar
OFF
Alarm (NO)
Alarm (NC)
Start
Clock (NO)
Clock (NC)
Dry running
External stop
Overpressure (NO)
Overpressure (NC)
0,5
0,5
Par. 5.05
Par. 5.05
The aim of this parameter is to enable signals remotely.
OFF:
The relay is never activated.
Alarm (NO):
The relay closes before an alarm.
Alarm (NC):
The relay opens before an alarm.
Start:
The relay is energised when the unit is running.
Clock (NO):
The relay closes depending on the time data programmed in
parameters 5.44 to 5.48.
Clock (NC):
The relay opens depending on the time data programmed in
parameters 5.44 to 5.48.
Dry running:
The relay is energised if the inverter detects dry running.
External stop:
The relay is energised when there is an external stop. (For this
condition we must have programmed a digital input as “Local Stop”).
Overpressure (NO):
The relay closes if there is overpressure alert (par. 5.49).
Overpressure (NC):
The relay opens if there is overpressure alert (par. 5.49).
If a 0-10V device is installed, here you can set the pressure value for the 1 volt
signal.
*This parameter is available when any of the digital input is set to Slave 0-10V.
If a 0-10V device is installed, here you can set the pressure value for the 9 volt
signal.
*This parameter is available when any of the digital input is set to Slave 0-10V.
A different setpoint can be set if the input is active.
A different setpoint can be set if the input is active.
A different setpoint can be set if the input is active.
A different setpoint can be set if the input is active.
See parameter 5.18
See parameter 5.18
See parameter 5.41
Start time of schedule program 1.
Start time of schedule program 2.
Stop time of schedule program 1.
Stop time of schedule program 2.
In this parameter you can choose not to have a schedule program (OFF) or the days
of the week that you want this program to run. You can choose between whole weeks
(M-Su), weekdays (M-F), weekends (Sa- Su) or individual days.
The schedule program will act on the output relay programmed for this purpose.
See parameter 5.18
RELAY OUTPUT 1
SLAVE 1V
PRESSURE SETPOINT
SLAVE 9V
PRESSURE SETPOINT
PRESSURE IN 1
PRESSURE IN 3
PRESSURE IN 2
PRESSURE IN 4
DIGITAL INPUT 2
DIGITAL INPUT 4
RELAY OUTPUT 2
PROGRAM START TIME 1
PROGRAM START TIME 2
PROGRAM STOP TIME 1
PROGRAM STOP TIME 2
SCHEDULE OPERATION 1
DIGITAL INPUT 3
Max.
Min.
Default
Units
Description
Par.
Programming
Notes
5.46
5.49
5.54
See parameter 5.43
Par 1,1
YES
FS
NO
OFF
FS
YES
Same as parameter 5.43 but for a second schedule program.
Parameter to set the maximum pressure value of the Hydraulic system.
Parameter for enabling or disabling the low water level alarm.
In the case of being active and cause notice, the drive will start attempts by the
following sequence:
5 minutes, 15 minutes, 1 hour, 6 hours or 24 hours. The display shows the remaining
time start attempt. Pressing F2 we force the reset of the notice, still unfinished
countdown.
If after the 24-hour notice is detected again dry running, the drive will lock
indefinitely until you press F2.
SCHEDULE OPERATION 2
OVERPRESSURE ALERT
LEVEL
DRY RUNNING ALARM
ACTIVE
Summary of Contents for emotion MT2-11A
Page 2: ......
Page 196: ...196 RU 1 2...
Page 200: ...200 RU c 5 11 3 1 4 2 2 9 11b 10 6 1 13 d 2 3 3 7 8 2 2 14 1 2...
Page 216: ...216 RU 0 5 17 F01 F02 F03 F04 F05 4 20 mA...
Page 217: ...RU 217 RU F06 F07 F08 A10 A11 A12 A15 ALARM X13 ALARM X14 NTC PTC PTC NTC A09 10 Hz 65 Hz...
Page 218: ...218 RU 18 19 20 2012 19 UE...
Page 243: ...TECHNICAL DATA...
Page 253: ......
Page 254: ...254 7 SCHEMATIC DIAGRAM TT3 30A 2 3 4 12 1 13 11b 11a 11b 7 9 15 14 8 17 5 6 16 10...
Page 257: ......
Page 260: ...260 N RU IT 49 01167 19 18 07 2019 17 07 2022 RU 31112 00011 www sacipumps com...
Page 261: ...261...
Page 262: ......