14 - LIST OF PARAMETERS
1.1
2.01
2.04
2.05
2.06
2.07
2.08
2.13
2.09
2.14
2.10
2.15
2.11
2.16
2.12
2.17
2.02
2.03
1.4
1.5
1.6
1.7
Bar
ºC
V
kohm
Hours
Hours
W
W
Wizard
0,5
FS
mA
mA
Amp
Wizard
0,1
MT2-11A
TT3-11A
TT3-30A
0
1
Hz
Wizard
0,1
99,9
Bar
0,5
0,3
3
Pressure you wish to maintain in the system.
This indicates the temperature the electronic module of the inverter.
This indicates the value of the 0-10V signal if it is enabled in one of the inputs.
This indicates the value of the NTC/PTC signal if it is enabled on settings.
This indicates the total number of hours the inverter has been connected to an electricity grid.
This indicates the total number of hours worked (providing an output voltage) of the inverter.
This indicates the total number of start-ups from zero that the unit has made.
This indicates whether the relay 1 output is ON or OFF.
This indicates whether digital input 1 is ON or OFF.
This indicates whether the relay 2 output is ON or OFF.
This indicates whether digital input 2 is ON or OFF.
Version of the unit software.
This indicates whether digital input 3 is ON or OFF.
Instantaneous power consumed in output terminals toward pump.
This indicates whether digital input 4 is ON or OFF.
Power consumed instantaneously by all of the pumps.
This indicates the value in mA of the pressure transducer 1.
This data will be 4 mA for 0 Bar and 20 mA for the upper limit of the transducer connected.
This indicates the value in mA of the pressure transducer 2.
This data will be 4 mA for 0 Bar and 20 mA for the upper limit of the transducer connected.
Current of the motor in amperes. Taking into account whether your motor is wired as
three phase 230V or three phase 400V. Insert nominal value.
You can change the rotation direction of the motor by modifying this parameter from
0 to 1 or vice versa.
The system will stop when the Inverter has been working for a certain time (see
parameter 5.12) under this frequency.
This is the differential that enables you to reduce the pressure to start the pump using
the value entered in parameter 1.1.
PRESSURE SETPOINT
MODULE TEMPERATURE
0-10V INPUT
MOTOR THERMISTOR
VOLTAGE HOURS
HOURS WORKED
START-UP NUMBER
RELAY 1 OUTPUT
DIGITAL INPUT 1
RELAY 2 OUTPUT
DIGITAL INPUT 2
SOFTWARE VERSION
DIGITAL INPUT 3
CONS. POWER OF PUMP
DIGITAL INPUT 4
CONS. POWER OF GROUP
ANALOGUE SIGNAL 1
ANALOGUE SIGNAL 2
MOTOR CURRENT
ROTATION DIRECTION
STOP FREQUENCY
START-UP DIFFERENTIAL
1. PARAMETERS
2. DISPLAY
Max.
Min.
Default
Units
Units
Description
Description
Par.
Par.
Programming
Notes
Notes
Summary of Contents for emotion MT2-11A
Page 2: ......
Page 196: ...196 RU 1 2...
Page 200: ...200 RU c 5 11 3 1 4 2 2 9 11b 10 6 1 13 d 2 3 3 7 8 2 2 14 1 2...
Page 216: ...216 RU 0 5 17 F01 F02 F03 F04 F05 4 20 mA...
Page 217: ...RU 217 RU F06 F07 F08 A10 A11 A12 A15 ALARM X13 ALARM X14 NTC PTC PTC NTC A09 10 Hz 65 Hz...
Page 218: ...218 RU 18 19 20 2012 19 UE...
Page 243: ...TECHNICAL DATA...
Page 253: ......
Page 254: ...254 7 SCHEMATIC DIAGRAM TT3 30A 2 3 4 12 1 13 11b 11a 11b 7 9 15 14 8 17 5 6 16 10...
Page 257: ......
Page 260: ...260 N RU IT 49 01167 19 18 07 2019 17 07 2022 RU 31112 00011 www sacipumps com...
Page 261: ...261...
Page 262: ......