External Control
118
D-73d Series Installation/Operation Manual
6.2
Using Discrete IR
Codes
The Dimension Digital Controller accepts commands in the form of IR signals that
conform to the NEC protocol. Each Dimension Digital Controller remote control button
has an NEC control code associated with it.
You can use these codes to program a third-party, “universal” remote control unit to
work with the Dimension Digital Controller. These third-party products usually come
with a computer software application for this purpose. For more information, consult the
documentation provided with the remote control unit.
IR Command Protocol
The IR control codes have the following characteristics:
• Each code consists of the following:
• A
leader pulse
(a modulated pulse of 9 ms followed by a non-modulated pulse of
4.5 ms);
• 16
address bits
. The default address is
82 09
(0x2011, binary
00100000 00010001). To change it, select Remote Control from the Service
menu and follow the steps given on page 91;
• 16
data bits
: eight (8) bits for the command followed by the logical inverse of the
command; and
• An
end pulse
(a modulated pulse of 0.56 ms, similar to the modulated pulse in
the ‘0’ and ‘1’ bits).The end of the modulated pulse constitutes the end of the data
transmission.
• The carrier frequency is 38 kHz, with the modulated pulses having a 33% duty cycle.
• Commands are sent at a maximum rate of 9 Hz.
For example, here is the NEC control code for the
ON
button on the Dimension Digital
Controller remote control unit (assuming the default address is used):
Figure 6-1 shows the pulse train for this command.
Figure 6-1. NEC Protocol Message Format
➤
Hex
20
11
01
FE
Binary
00100000
00010001
00000001
11111110
Function
Address Byte 1
Address Byte 2
Command
Command
(Logical Inverse)
9 ms
13.5 ms
27 ms
27 ms
Address Byte 1
Leader Pulse
Address Byte 2
Command Byte
Command Byte (logical inverse)
0 0 1 0 0 0 0 0 0 0 0 1 0 0 0 1
0 0 0 0 0 0 0 1
1 1 1 1 1 1 1 0
4.5 ms
End Pulse
Summary of Contents for D-73d Ultra
Page 2: ......
Page 14: ...Table of Contents xiv D 73d Series Installation Operation Manual...
Page 22: ...Introduction 6 D 73d Series Installation Operation Manual Notes...
Page 36: ...System Overview 20 D 73d Series Installation Operation Manual Notes...
Page 114: ...Operation 98 D 73d Series Installation Operation Manual Notes...
Page 150: ...Specifications 134 D 73d Series Installation Operation Manual Notes...
Page 151: ......
Page 152: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1082 02 Rev A March 2014...