Maintenance and Troubleshooting
100
D-73d Series Installation/Operation Manual
Identifying the Left and Right Polarizers:
Although the left and right polarizers have
very different optical characteristics, they appear to be identical. As a result, once you
remove them from the projector it may be difficult to tell them apart. Use the following
technique to verify which one is which:
1. Place the polarizer on a clean, smooth, flat surface with the side that faces the
projector facing up.
2. Hold a pair of 3D glasses above the polarizer as shown here:
3. If the right lens on the glasses turns black when it is above the polarizer, this tells you
that the polarizer came from the left-eye optical engine on the projector.
Troubleshooting
Table 5-1 provides some general guidelines for troubleshooting problems you may
encounter with the D-73d Series LED 3-D Home Theater Projection System. If the
suggested solutions fail to resolve the problem or if you encounter an issue not
described here, please contact your Runco dealer or Runco Technical Support.
572-2479-00REV00
572-2479-00REV00
Left Polarizer*
Left Polarizer*
* viewed from the side facing the projector
3D Glasses
L
R
L
R
Same Angle of
Polarization
(light passes)
Different Angles
of Polarization
(light does
not pass)
➤
Table 5-1. Troubleshooting Chart
Symptom
Possible Cause(s)
Solution
The projector does not turn
on.
• The projector is not
plugged in or the AC outlet
is not active.
• The Dimension Digital
Controller is not plugged in
or the AC outlet is not
active.
• The remote control
batteries have run out.
• Ensure that the projector is
plugged in and that the AC
outlet is active.
• Ensure that the Dimension
Digital Controller is
plugged in and that the AC
outlet is active.
• Replace the batteries.
The “left-eye” optical engine
does not turn on or respond
to user commands. The vac-
uum fluorescent display on
the Dimension Digital Control-
ler front panel displays the fol-
lowing message:
Primary Display Error
Communication Failure
• The serial connection from
the Dimension Digital
Controller to the “left-eye”
optical engine on the
display is incorrect or the
cable is faulty.
• Ensure that the
Pri Display Control
(RS-232) output from the
Dimension Digital
Controller is properly
connected to the display
(see Figure 3-14).
Summary of Contents for D-73d Ultra
Page 2: ......
Page 14: ...Table of Contents xiv D 73d Series Installation Operation Manual...
Page 22: ...Introduction 6 D 73d Series Installation Operation Manual Notes...
Page 36: ...System Overview 20 D 73d Series Installation Operation Manual Notes...
Page 114: ...Operation 98 D 73d Series Installation Operation Manual Notes...
Page 150: ...Specifications 134 D 73d Series Installation Operation Manual Notes...
Page 151: ......
Page 152: ...Runco International 800 23RUNCO Fax 503 748 8161 www runco com 020 1082 02 Rev A March 2014...