7.1.7 Air pressure alarm
When cutting, when the main board detects that the air pressure alarm input (general input
port I11) is low, the main board will generate a gas pressure alarm. If it is in processing, the
processing will be suspended. If you need to continue processing, please eliminate the alarm
first, and then continue processing, otherwise you will not be able to continue processing.
7.1.8 Large following error
In the cutting head following state, when the following error is greater than the setting value,
an alarm with an excessive following error is generated. If the "following error too large" alarm is
frequently triggered during the cutting process, the maximum following error parameter needs to
be increased.
7.1.9 Encoder error
When the Z-axis servo motor cannot be a closed-loop control, an encoder error will occur,
which may be the following situation:
The encoder connection is incorrectly. Please check the Z-axis servo driver wiring.
The encoder polarity setting is incorrect. Please set the encoder polarity correctly.
7.1.10 X
、
Y
、
U
、
A Axis servo alarm
When the board detects that the servo alarm signal input in high voltage, a servo alarm will
be generated, or when the servo motor may have unsafe operation, a servo alarm will also be
generated. There are several situations in which a servo alarm may occur:
The servo drive has generated an alarm
Servo driver servo alarm signal voltage logic is incorrect. When the servo driver alarms,
the output must be high voltage. If it is the low voltage, please switch the voltage to high
voltage by relay or other ways.
The wiring is wrong, please check the connection.
Poor grounding, resulting in large system interference, resulting in false triggering of the
alarm, please ensure that the machine is well grounded.
7.1.11 Z Axis servo alarm
When the board detects that the Z-axis servo alarm signal input in high voltage, a servo