3.5 Vendor parameters
Press the [Vendor] button in the main interface. If it is the first time to use, the password
input interface will pop up. Only after entering the correct password then you can enter. After
successful entry, the following interface pops up:
The Y1 axis interface is the same as the Y2 axis
When modifying the parameters of the three-color lamp configuration page, select a
parameter and press the [Enter] key to switch the enable state. Red means enable, gray means
disable.
Other interface operations and settings of the vendor parameters are the same as the user
parameter interface, and will not be described here.
The manufacturer parameters are detailed in the following table:
X
、
Y1
、
Y2
、
U
、
A axis
Directional
polarity
Modifying the direction polarity allows the motor to move
in the opposite direction. The target of the modification is
to make the axis move to the origin when resetting. If the
axis moves away from the origin when resetting, it
indicates that the polarity of the axis is set incorrectly and
should be modified.
Limit polarity
Used to set the high and low mode of the limit signal. If
the motion axis reaches the limit position, input a low
voltage signal to the main board, then the limit polarity
should be set to negative.
control mode
The types of controller output pulses include positive and