RDC6563F Standalone Fiber Cutting Control System User Manual V2.0
63
SHENZHEN RUIDA TECHNOLOGY CO., LTD
At this time, press the direction key to change the coordinate value of the X/Y axis, press the
[Position] key to set the current coordinate value to the positioning point 1, and finally press the
[Exit] key to return to the last interface. Other anchor point setting methods are the same as
above.
The various sub-options are described as follows:
Multiple positioning points enable: [Enable], [Disable] can be selected. When [Disable]
is selected, the system uses single positioning point logic, press the [Position] key on
the keyboard to set the positioning point, and only this positioning point works. When
[Yes] is selected, the system uses multiple positioning point logic, and the [Positioning]
key on the keyboard is invalid. The values of the individual positioning points need to be
set in the menu, see below.
Locating points 1 to 4 enable: When multiple positioning point logic is enabled, the four
positioning points can be individually disabled and enabled.
Start positioning point: 0~4 is optional, showing the positioning point to be used in the
next picture to be worked. The 0th positioning point indicates the positioning point set
by the [Positioning] key on the panel of the single positioning point logic, and the 1~4
indicates the positioning point number in the multi-positioning point logic. The next
positioning point can be modified to any point from 1 to 4, so as to control the starting
position of the next working time (in the condition of the positioning point is enabled),
and cannot be modified to the positioning point of 0 (if it is a single positioning point
logic, it will always take 0) Number anchor point).
Important:
Once the multi-locating point logic is selected, If the starting
anchor point number is 1, and all four positioning points are
enabled, when the memory file is started (including keyboard
startup and PC startup), or when the PC starts working with
direct output and When the "Use original positioning point as the