Q9
General output IO
Gas 2 control signal, low voltage valid, it
can control the relay to control the
solenoid valve directly
Q10
General output IO
Gas 3 control signal, low voltage valid, can
control the relay to control the solenoid
valve directly
Q11
General output IO
Reserved
Q12
General output IO
Reserved
Q13
General output IO
Reserved
Q14
General output IO
Reserved
Q15
General output IO
Reserved
24V
+24V power
(
output
)
cont24V power output, current
output capability is more than 2A
All output IO use OC output to drive the relay directly, the maximum current can reach 500mA,
and the wiring diagram is as follows:
Auxiliary gas wiring instructions
:
When using one gas, you can arbitrarily select one channel from the three gas channels as
the blowing channel, and the gas is set as a cutting gas and a perforated gas in the layer. If
the relay is connected to the pin Q9, then the layer parameter cutting gas and the punching
gas need to be set to gas 2, and so on.
When two gases are used, two channels can be arbitrarily selected from the three gas
channels as the blowing channels. If the high pressure gas is connected to the pin Q9 and
the low pressure gas is connected to the pin Q10, the layer parameter cutting gas needs to
be set to gas 2, and the perforated gas is set to gas 3.The same as other channels.