Invert Input B Check Box
The
Invert Input B
check box is used to reverse the input condition.
For example, if the input condition is “Talk Key”, which by itself means, when a specified talk key is on, run the assigned
output. However, by selecting the Invert Input A check box, it means changes to when a specified talk key is off, run the
assigned output.
The invert check box is often used in one UPL statement to cancel an action caused by some other UPL statement.
Output Action Group Box
Type and Variable Drop Down Menus
The
Type and Variable
drop down menu is used to select an output result that occurs when an input definition is met.
Depending on which is selected from the
Type
drop down menu, dictates what variable is needed.
Use Table 14 on page 66 to determine the type and variables you want to use.
TABLE 14.
Output Values
Output
Output Description
Variables Needed
Close Crosspoint
Close the crosspoint from the specified
input to the specified output
Input Number, Alpha, Output Number, Alpha
Inhibit Crosspoint
Open the crosspoint from the specified
input to the specified output.
Input Number, Alpha, Output Number, Alpha
Assert GPI Output
Activate the specified System GPI
Output
GPI Output Number and Alpha
Inhibit GPI Output
Deactivate the specified System GPI
Output
GPI Output Number and Alpha
Assert GPI Output (Local)
Activate the specified Local GPI Output
Port Number and Alpha, GPI Output Number
and Alpha
Inhibit GPI Output (Local)
Deactivate the specified Local GPI
Output
Port Number and Alpha, GPI Output Number
and Alpha
Force Talk Key Closure
Force the specified talk key ON
Port Number, Alpha and Key Number
Force Talk Key Open
Force the specified talk key OFF
Port Number, Alpha and Key Number
Dim Crosspoint Volume
Cause the specified output to hear the
specified input at a reduced volume
level.
Input Number, Alpha, Output Number, Alpha
and DIM amount (-1.0dB to -72.2dB, and
Mute)
Load File
Cause a file to be loaded from disk and
sent to the intercom system.
NOTE:
AZedit must be in SERVER
mode.
The Load File pulls files from the directory you
have configured on the General page in the
Preferences window.
Force Listen Key Closure
Force the specified listen key ON
Port Number, Alpha, and Key Number
Force Listen Key Open
Force the specified listen key OFF
Port Number, Alphas, and Key Number
Clear Counter
Clear the Counter
Clears the counter input from the UPL
statement. If you select 0 all counters are
cleared
Inhibit Output
Open the output port.
Output Port Number, and Alpha
Summary of Contents for Zeus III
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05 4 Zeus III...
Page 26: ...26 Introduction Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 30: ...30 Cables Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 56: ...56 Zeus III and VOX Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 69: ...Zeus III 69 Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05 Notes...