Zeus III
65
Bosch Security Systems, Inc.
Technical Manual
F.01U.193.289
Rev. 05
Input B Group Box
Type and Variable Drop Down Menus
The
Type
and
Variable
drop down menu is used to select an input condition that causes the intercom system to perform an
output action. Each UPL statement can have either one (1) or two (2) input conditions. Depending on which is selected from
the Type drop down menu. Use Table 13 on page 65 to determine the type and variables you want to use.
TABLE 13.
Input B Types and Variables
Input
Condition
Input Description
Variables Needed
UPL Statement
If a specified UPL statement is true...
UPL Statement # and Description
GPI Input
If a system GPI Input is activated....
GPI Input # and Alpha
GPI Input (Local)
If a Local GPI Input is activated...
Port # and Alpha
GPI Input # and Alpha
GPI Output
If a system GPI Output is activated...
GPI Output # and Alpha
GPI Output
(Local)
If a Local GPI Output is activated...
Port # and Alpha
GPI Output # and Alpha
Talk Key
If a specified Talk Key on a keypanel is ON...
Port # and Alpha
Key #
Listen Key
If a specified Listen Key on a keypanel is ON...
Port # and Alpha
Key #
UPL Resource
If a UPL Resource key is activated...
UPL Resource # and Description
Crosspoint
If a specified Crosspoint is activated...
Input # and Alpha
Output # and Alpha
Input Talking
If a specified port is talking to anyone...
Input # and Alpha
Output Listening
If a specified port is listening to anyone...
Output # and Alpha
Headset Transfer
If the Headset Transfer switch on a keypanel is
activated...
Port # and Alpha
Target Date
If the Target Date is...
Year, Month, and Day (YY/MM/DD).
NOTE:
Target Date is used in conjunction
with Current Date.
Target Time
Target Time is used in conjunction with Current Time.
Hour, Minute, Second (00:00:00)
NOTE:
All times are entered in the 24-hour
or military time format. For
example, 1:00 pm is 13:00:00.
NOTE:
Target Time is used in conjunction
with Current Time.
IFB Interrupted
If the specified IFB is interrupted...
IFB # and Alpha
Target Value
Target Value is used in conjunction with the Counter
input.
NOTE:
Automatically switches input A to
Counter.
The target value is an increment of time, in ms, to
trigger an event. 1 counter equals 100ms.
The counter input selection is used to write UPL
statements to occur in a timed event. For example,
when a key is pushed, wait 10 seconds before running
the UPL statement to turn a light ON.
Vox Audio
If Vox Audio is...
Input # and Alpha
Any Talk Key
If Any Talk Key is on a keypanel is ON....
Port # and Alpha
Call Signal
If a Call Signal is detected
Port # and Alpha
Summary of Contents for Zeus III
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05 4 Zeus III...
Page 26: ...26 Introduction Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 30: ...30 Cables Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 56: ...56 Zeus III and VOX Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 69: ...Zeus III 69 Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05 Notes...