Input A Group Box
Type and Variable Drop Down Menu
The
Type and Variable
drop down menu is used to select an input condition that causes the intercom system to perform an
output action. Each UPL statement can have either one (1) or two (2) input conditions. Depending on which is selected from
the Type drop down menu, dictates what variable is needed.
Use Table 12 on page 63 to determine the type and variables you want to use.
TABLE 12.
Input A and Variables
Input Condition
Input Description
Variables Needed
UPL Statement
If a specified UPL statement is true...
UPL Statement # and Description
GPI Input
If a system GPI Input is activated....
GPI Input # and Alpha
GPI Input (Local)
If a Local GPI Input is activated...
Port # and Alpha
GPI Input # and Alpha
GPI Output
If a system GPI Output is activated...
GPI Output # and Alpha
GPI Output (Local)
If a Local GPI Output is activated...
Port # and Alpha
GPI Output # and Alpha
Talk Key
If a specified Talk Key on a keypanel is ON...
Port # and Alpha
Key #
Listen Key
If a specified Listen Key on a keypanel is ON...
Port # and Alpha
Key #
UPL Resource
If a UPL Resource key is activated...
UPL Resource # and Description
Crosspoint
If a specified Crosspoint is activated...
Input # and Alpha
Output # and Alpha
Input Talking
If a specified port is talking to anyone...
Input # and Alpha
Output Listening
If a specified port is listening to anyone...
Output # and Alpha
Headset Transfer
If the Headset Transfer switch on a keypanel is
activated...
Port # and Alpha
Current Date
If the Current Date is...
Year, Month, and Day (YY/MM/DD).
NOTE:
You must use the Operator drop down menu
when using the Date and/or Time input.
Current Time
If the Current Time is...
Hour, Minute, Second (00:00:00)
All times are entered in the 24-hour or military time
format. For example, 1:00 pm is 13:00:00.
NOTE:
You must use the Operator drop down menu
when using the Date and/or Time input.
IFB Interrupted
If the specified IFB is interrupted...
IFB # and Alpha
Counter
If the Counter is...
NOTE:
Counters count increments of time.
Each counter is equal to 100ms of
time. AZedit allows for up to 256
counters to be used.
The counter input selection is used to write UPL
statements to occur in a timed event. For example,
when a key is pushed, wait 10 seconds before running
the UPL statement to turn a light ON.
Counter #
NOTE:
You must use the Operator drop down menu
when using the Counter input.
Vox Audio
If the Vox Audio is...
Input # and Alpha
Any Talk Key
If Any Talk Key is on a keypanel is ON....
Port # and Alpha
Call Signal
If a call signal is detected....
Port # and Alpha
Summary of Contents for Zeus III
Page 4: ...Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05 4 Zeus III...
Page 26: ...26 Introduction Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 30: ...30 Cables Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 56: ...56 Zeus III and VOX Zeus III Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05...
Page 69: ...Zeus III 69 Bosch Security Systems Inc Technical Manual F 01U 193 289 Rev 05 Notes...