![RST FRC-F Series Manual Download Page 77](http://html1.mh-extra.com/html/rst/frc-f-series/frc-f-series_manual_1496813077.webp)
9.581.140-6
Page:
77
9.7.4.2 Digital inputs
Here, you can configure the 3 digital inputs DigIn 1, DigIn 2 und DigIn 3
of the converter. The menus are the same for all 3 digital inputs. For this
reason, the configuration options are explained for digital input 1 only:
Note: If the temperature monitor of the brake resistor is used (refer to
Chapter 5.2.1.5)
, the digital
input 2 can not be changed !
9.7.4.2.1 External fault acknowledgement
"
External fault acknowledgement input
" function. A fault can be
acknowledged by an ex24V signal on this input.
9.7.4.2.2 Monitoring drive contactors
"
Monitoring drive contactors
" function. This function is only required in
combination with our converter with integrated contactors. The drive
contactors are checked for a drop at a standstill (500 msec after opening
the ZS relay) via auxiliary contacts.
9.7.4.2.3 Monitoring of opening brake upon start
Function „
Monitoring of opening of brake upon start
“. Via a +24 V
signal the VVVF controller is informed that the brake is open. The set
value will start only when the digital input switches to +24 V.
Note: If several digital inputs are programmed with this function, they all
must be at +24 V (AND link)
9.7.4.2.4 Brake monitoring as per EN81/A3
The VVVF controller is used for monitoring of the power brake according
to EN81-A3. For more info, refer to
Chapter
9.7.7
.
9.7.4.2.5 Emergency power
The VVVF controller receives information about emergency power
operation. For more info, refer to
Kapitel
Fehler! Verweisquelle konnte
nicht gefunden werden..
Functionality of
digital input 2:
(see digital input 1)
Functionality of
digital input 3:
(see digital input 1)
Inputs/outputs
Digin 1
----------------------
Digin 1
Error Ack.(0)
----------------------
Digin 1
Contact. Mon. (1)
----------------------
Inputs/outputs
Digin 2
----------------------
Digin 1
Brake Start
----------------------
○
Inputs/outputs
Digin 2
----------------------
Digin 1
BrakeMon.EN81
----------------------
○
Digin 1
EmergencyPower
----------------------
○
Summary of Contents for FRC-F Series
Page 1: ...9 581 140 6 Page 1 VVVF Controller for Elevators FRC Q FRC F IMD...
Page 16: ...9 581 140 6 Page 16...
Page 17: ...9 581 140 6 Page 17...
Page 23: ...9 581 140 6 Page 23...
Page 85: ...9 581 140 6 Page 85...
Page 90: ...9 581 140 6 Page 90...
Page 122: ...9 581 140 6 Page 122...
Page 123: ...9 581 140 6 Page 123...
Page 124: ...9 581 140 6 Page 124...
Page 125: ...9 581 140 6 Page 125...