![RST FRC-F Series Manual Download Page 133](http://html1.mh-extra.com/html/rst/frc-f-series/frc-f-series_manual_1496813133.webp)
9.581.140-6
Page:
133
15.1.18
Calibration
Causes and remedy:
An error has occurred during the calibration of the synchronous machine.
Consult RST.
15.1.19
Earth fault
Triggered:
The measured earth fault current exceeds the permissible value.
Causes and remedy:
High EMC impact.
Motor defective.
Check shields and RC-elements of contactors.
Check if large interference sources (e.g. large machines, …) are located near the converter.
Measure motor.
15.1.20
Motor overload
Triggered:
The load limit of the motor was exceeded.
Causes and remedy:
Wrong parameterisation.
Incremental encoder defective.
Motor possibly too small.
Check parameterisation.
Consult RST.
15.1.21
Sine amplitude
Triggered:
Amplitude of sine signals is outside of permissible range.
Causes and remedy:
sine encoder defective
Wrong D-SUB connector configuration, or connector not plugged.
Check sine encoder wiring.
Consult RST.
15.1.22 CDAmplitude
Triggered:
Amplitude of CD-Signale (encoder ERN1387) outside of tolerance range.
Causes and remedy:
Sine encoder defective.
Wrong D-SUB connector configuration or connector not plugged.
Check sine encoder wiring.
Consult RST.
15.1.23
Referencing error
Triggered:
In the case of CD encoder, if no zero pulse was found after 60 s of travel.
Causes and remedy:
Consult RST.
Summary of Contents for FRC-F Series
Page 1: ...9 581 140 6 Page 1 VVVF Controller for Elevators FRC Q FRC F IMD...
Page 16: ...9 581 140 6 Page 16...
Page 17: ...9 581 140 6 Page 17...
Page 23: ...9 581 140 6 Page 23...
Page 85: ...9 581 140 6 Page 85...
Page 90: ...9 581 140 6 Page 90...
Page 122: ...9 581 140 6 Page 122...
Page 123: ...9 581 140 6 Page 123...
Page 124: ...9 581 140 6 Page 124...
Page 125: ...9 581 140 6 Page 125...