Page - 88 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Dry Powder Unit
Two dry powder units are installed in the compartment behind the
cabin. Both dry powder units are connected with the twin agent
hose reel, located in the left locker compartment and equipped with
non-collapsible hose and dry powder pistol.
The hose reel can be powder supplied either by the left or right dry
powder unit.
For further information please refer to the manufacturer's opera-
tion manual.
Controls and indications of the dry powder unit
26
hose guide frame
DPU control panel for the dry powder unit - for further informa-
tion please refer to the manufacturer's operation manual
JC_
nitrogen bottle with manually and pneumatically valve
drive
J99
twin-agent nozzle - not shown
J102 left twin-agent hose reel without non collapsible rubber hoses
S116 rewinding switch: for rewinding purposes always release
the brake (Z102), operate switch whilst guiding the hose
carefully and without tension then apply brake (Z102)
again
XTF1 external filling connection for nitrogen bottle (JC1)
XTF2 external filling connection for nitrogen bottle (JC2)
Z99
hose reel crank - placed below the hose reel
Z102 hose reel-brake lever
Z108 connection for hose reel crank
Rewinding the hose manually:
- Release hose reel brake (Z102).
- Put on the hose reel crank (Z99) to connection (Z108).
◊
Rewind the hose as to be only very slightly tensioned and
guide it exactly.
- Lock brake (Z102) again.
Dry Powder Unit
ATTENTION !
The rapid intervention system is connected to the dry powder unit;
the pressure is up to 16 bar. Therefore it is strictly prohibited to aim
the jet of the nozzle at any persons; severe injuries may occur !
It is strictly advised to use the installed rapid intervention device
for fire fighting only. Any other use is strictly prohibited by
Rosenbauer.
In cases of misuse, Rosenbauer is not liable for any injury or damage.
JC2
JC1
S116
26
Z102 Z108 Z99
XTF1
J102
XTF2
DPU