Page - 63 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
8%
3%
Air Crash Mode
ATTENTION !
The pump system must be flushed after every foam operation.
Please refer to the "Flushing after Foam Operation" chapter.
Manual Pump Operation
ATTENTION !
If the automatic mode fail to work the pump system can be operated
manually.
Procedure:
- Shift pump system to manual mode:
◊
Press switch (S54), the integrated pilot lamp illuminates.
- Engage the pump:
◊
Please refer to the "Engaging the Pump" chapter.
- Open the water tank suction valve:
◊
Press switch (S11), the integrated pilot lamp illuminates.
- Prime the pump system:
◊
Press switch (S3) until a pressure of max. 2 bar is achieved
(visible on water pressure gauge (P6)).
◊
During priming operation accelerate to approx. 1000 rpm
engine speed (visible on rpm gauge (P14)) by using switch
(S9+).
◊
The pump icon (J1) illuminates blue as long as the priming
pump is engaged.
- Operate turrets and undertruck nozzles as described before.
- Adjust required discharge pressure and throwing range:
◊
Press switch (S9+) to increase the pump speed.
◊
Press switch (S9-) to decrease the pump speed.
S9-
S54 S11
S3
S9+
xx,x bar
xxxx U/min
x %
xx °C
xxx h
P6
J1
P14