Page - 75 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Handline Operation
Handline Operation
- Connect the pressure hoses to the left and/or right pressure
outlets (J11).
- Connect the pressure hoses to the left and/or right pressure
outlets (J11h). *
- Connect branch pipes to the pressure hoses.
- Pull out the collapsible hoses completely before opening a
discharge valve.
- Operate the pump as mentioned in the
◊
"Manual Pump Operation" or
◊
"Air Crash Mode Operation" chapter.
- Open the left and/or right discharge valve(s) (J10) slowly.
- Open required handline discharge valve(s): *
◊
Press switch (S44) to open the left bottom regulated dis-
charge valve. *
◊
Press switch (S45) to open the right bottom regulated discharge
valve. *
- Adjust required discharge pressure:
◊
With "Manual Pump Operation" use switch (S9+) to in-
crease the pump speed or switch (S9-) to decrease the pump
speed.
Note:
A pressure reduction valve, mounted into the discharge lines
(J11h), reduces the discharge pressure for handlines to approx. 7
bar. *
The handline and the regulated handline discharge valves can be
controlled from the pump control panel in the cabin as well as form
an external pump control panel. *
8%
3%
S9-
S9+
S45
S44
J10
J11
J10
J11
CAUTION !
- Before opening a handline discharge valve, completely pull out
the collapsible hose.
- Before opening a handline discharge valve make sure that the
nozzles are held tightly - danger of water hammer effect!
- Release pressure before disconnecting a hose!