Page - 52 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Air Crash Mode
Description of control handle of RM 60 C
The turret is remotely controlled from the drivers cabin. This is
done by a control handle. The turret follows the movement of this
control handle.
20
control handle
H65
position LED
S46
START - switch
S47
STOP - switch
S48
discharge reduction switch
◊
"OFF" position -> full output
◊
"ON" position -> half output; the integrated pilot lamp
illuminates
S49f
roof turret deflector adjustment switch -> full jet
S49s
roof turret deflector adjustment switch -> spray
S50
toggle switch for turret discharge valve
S488 permanent roof turret discharge switch - with integrated
pilot lamp which indicates open discharge valve
Note:
The windshield wipers are engaged with roof turret's discharge
valve open.
The roof turret will always start with full discharge amount
selected.
20
S488
S49s
S49f
S46
H65
S48
S47
S50
ATTENTION !
Operate the roof turret with closed roof hatch only !
20
CAUTION !
Before activating the turret control please make sure to have
enough operation area available. The turret moves automatically
into the same position like the control handle is pointing to.
Never point the discharge jet at anybody.
DANGER OF INJURY TO PERSONNEL!