Page - 42 -
FLF 15000/1800/500
Panther 8x8 CA-7
© 2014
Technical Description
J77
M57
Z78
81
M58
Further installations in the pump compartment
81
oil fill plug of the priming pump
J61r
revision valve of the foam compound tank
Note:
valve open -> this is the normal operation position
Close the revision valve only during maintenance or service
work.
J77
foam induction valve
Note:
valve open -> this is the normal operation position
Close the foam induction valve only for a pump perform-
ance test.
M57
adjusting motor for small proportioning rate
M58
adjusting motor for big proportioning rate
Z78
bolt for manually foam proportioning adjustment
Note:
For further information please refer to the "Emergency
Adjustment of the Foam Proportioning Rate" chapter.
Oil level check system for pump gearbox and priming pump
H88/1 pilot lamp: priming pump oil level indication
H88/2 pilot lamp: pump gearbox oil level indication
S555 switch: oil level check
◊
"left" position -> to check the system for proper function
◊
"centre" position -> system disengaged
◊
"right" position -> to check both oil levels
Note:
For further information please refer to the "Service
Procedures" chapter.
H88/1
H88/2
S555
J61r