![Rosemount 8712 Reference Manual Download Page 95](http://html1.mh-extra.com/html/rosemount/8712/8712_reference-manual_1487460095.webp)
Reference Manual
00809-0100-4664, Rev BA
January 2010
5-11
Rosemount 8712
3.
Place the sensor between the flanges. Make sure that the centering
rings are properly placed in the studs. The studs should be aligned
with the markings on the rings that correspond to the flange you are
using.
4.
Insert the remaining studs, washers, and nuts.
5.
Tighten to the torque specifications shown in Table 5-5. Do not
overtighten the bolts or the liner may be damaged.
NOTE
On the 4- and 6- inch PN 10-16, insert the sensor with rings first and then
insert the studs. The slots on this ring scenario are located on the inside of the
ring.
Figure 5-11. Gasket Placement
with Centering Rings
Flange Bolts
Sensor sizes and torque values for both Class 150 and Class 300 flanges are
listed in Table 5-5. Tighten flange bolts in the incremental sequence, shown in
Figure 5-10.
NOTE
Do not bolt one side at a time. Tighten each side simultaneously. Example:
1. Snug left
2. Snug right
3. Tighten left
4. Tighten right
Do not snug and tighten the upstream side and then snug and tighten the
downstream side. Failure to alternate between the upstream and downstream
flanges when tightening bolts may result in liner damage.
Always check for leaks at the flanges after tightening the flange
bolts. All sensors require a second torquing 24 hours after initial flange bolt
tightening.
Table 5-4. Stud Specifications
Nominal Sensor Size
Stud Specifications
0.15 – 1 inch (4 – 25 mm)
316 SST ASTM A193, Grade B8M
Class 1 threaded mounted studs
1
1
/
2
– 8 inch (40 – 200 mm)
CS, ASTM A193, Grade B7, threaded mounting studs
Customer-supplied
Gasket
FLOW
Installation, Studs
Nuts and Washers
Centering Rings
See ”Safety Messages” on pages 5-1 and 5-2 for complete warning information.
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......