DC Load Limitations (Analog Output)
Maximum loop resistance is determined by the voltage level of the external
power supply, as described by:
FIGURE 1. DC Load Limitations
NOTE
Field Communication requires a minimum loop resistance of 250 ohms.
Supply Current Requirements
Units powered by 12-42 V DC power supply may draw up to 1 amp of current
steady state.
FIGURE 2. DC Current Requirements
Power Consumption
10 watts maximum
Ambient Temperature Limits
Operating
-20 to 140 °F (-29 to 60 °C) with local operator interface
-40 to 165 °F (-40 to 74 °C) without local operator interface
Storage
–40 to 176 °F (–40 to 80 °C)
R
max
=
41.7(V
ps
– 10.8)
V
ps
=
Power Supply Voltage (Volts)
R
max
=
Maximum Loop Resistance (Ohms)
Power Supply (Volts)
Lo
ad (Oh
m
s)
Operating
Region
1250
1000
500
0
10.8
42
12
18
24
30
36
42
0.0
0.3
0.8
1.0
0.5
Power Supply (Volts)
Sup
p
ly C
u
rrent (Am
p
s
)
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......