Reference Manual
00809-0100-4664, Rev BA
January 2010
6-7
Rosemount 8712
Meter output is unstable
Medium to low conductivity fluids (10–
25 microsiemens/cm) combined with
cable vibration or 60 Hz interference
Eliminate cable vibration:
• Integral mount
• Move cable to lower vibration run
• Tie down cable mechanically
• Trim electrode and coil wires
• See “Conduit Cables” on page 2-6
• Route cable line away from other equipment
powered by 60 Hz
• Use 8712-0752-1,3 cable
Electrode incompatibility
Check the Technical Data Sheet, Magnetic Flowmeter Material
Selection Guide (document number 00816-0100-3033), for
chemical compatibility with electrode material.
Improper grounding
Check ground wiring – see “Mount the Transmitter” on page 2-3
for wiring and grounding procedures
High local magnetic or electric fields
Move magnetic flowmeter (20–25 ft away is usually acceptable)
Control loop improperly tuned
Check control loop tuning
Sticky valve (look for periodic
oscillation of meter output)
Service valve
Sensor failure
Perform the sensor Tests A, B, C, and D
(See Table 6-6 on page 6-9)
Analog output loop problem
Check that the 4 to 20 mA loop matches the digital value.
Perform analog output test.
Reading does not appear to be
within rated accuracy
Transmitter, control system, or other
receiving device not configured
properly
Check all configuration variables for the transmitter, sensor,
communicator, and/or control system
Check these other transmitter settings:
Sensor calibration number
Units
Line size
Electrode coating
Use bulletnose electrodes in the Rosemount 8705 Sensor.
Downsize the sensor to increase the flow rate above 3 ft/s.
Periodically clean the sensor
Air in line
Move the sensor to another location in the process line to
ensure that it is full under all conditions
Flow rate is below 1 ft/s
(specification issue)
See the accuracy specification for specific transmitter and
sensor
Insufficient upstream/downstream
pipe diameter
Move sensor to location where 5 pipe diameters upstream and 2
pipe diameters downstream is possible
Cables for multiple magmeters run
through same conduit
Run only one conduit cable between each sensor and
transmitter
Auto zero was not performed when the
coil drive frequency was changed from
5 Hz to 37.5 Hz
Perform the auto zero function with full pipe and no flow
Sensor failure—shorted electrode
Sensor failure—shorted or open coil
Transmitter failure
Replace the electronics board
Transmitter wired to correct sensor
Check wiring
Table 6-5. Advanced Troubleshooting–Rosemount 8712
Symptom
Potential Cause
Corrective Action
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......