Rosemount 8712
Auxiliary Functions
Function
Run 8714i
Operating Mode
Coil Pulse Mode
Flow rate Display
Totalizer Display
Totalizer Units
Configure Signal Processing
Special Units
Process Density
DI/DO 1 Config
Digital Output 2
Flow Limit 1
Flow Limit 2
Totalizer Limit
Diagnostic Status Alert
Reverse Flow Enable
Licensed Options
License Key
Diagnostics Enable
8714i Setup
Re-signature Sensor
Recall Last Signature
Empty Pipe
Universal Auto Trim
Low Flow Cutoff
Pulse Width
Analog Output Zero
Analog Output Test
Pulse Output Test
Transmitter Test
4–20 mA Output Trim
Auto Zero
Electronics Trim
Options
Runs the meter verification diagnostic
Normal or Filter
5 or 37 Hz
Flow–% Span, Flow–Totalize, %Span–Totalize
Forward–Reverse or Net–Gross
Configure the totalizer units of measure
On/Off
Volume units, base volume units, conversion, time base, rate units
Required for units of mass flow
Configure Auxiliary Channel 1
Configure Auxiliary Channel 2
Configure Flow Limit 1 Alert
Configure Flow Limit 2 Alert
Configure Totalizer Limit Alert
Configure Diagnostic Status Alert
On/Off
Displays Licensed Options
Field license advanced functionality
Turn diagnostics On/Off
Configure test criteria parameters
Base line sensor characteristics
Recall previous signature values
Configure empty pipe diagnostic parameters
In-process Sensor Calibration
0.01 ft/s to 1 ft/s
Pulse Width
4 mA Value
Analog Output Loop Test
Pulse Output Loop Test
Test the Transmitter
Adjust the 4–20 mA Output
Zero Sensor for 37 Hz Coil Drive Operation
Transmitter Calibration
Analog Output Range
Sets the desired 20 mA point –
must
set the sensor size first
Pulse Output Scaling
Sets one pulse to a selectable number of volume units –
must
set the sensor size first
Damping
Sets response time (single pole time constant), in seconds, to a step change in flow rate
Transmitter Information
Allows you to view and change useful information about the transmitter and sensor
Empty Pipe Tuning
Allowable range 3.0 - 2000.0
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......