Connect coil drive and electrode cables as shown in Figure E-6.
Figure E-6. Wiring Diagram for
ABB Magmaster MFE and MFF
Sensors (New Version) and
Rosemount 8712
Table E-4. ABB Magmaster MFE and MFF Sensors (New Version) Wiring
Connections
Rosemount 8712
ABB Magmaster MFE and
MFF Sensors (New Version)
1
Red
2
Yellow
17
18
Pink
19
Blue
Grey
Pink
Blue
White
Violet
Yello
w
Red
ABB MAGMASTER MFE
AND MFF SENSORS
(NEW VERSION)
ROSEMOUNT 8712
TRANSMITTER
This is a pulsed dc magnetic flowmeter.
Do
not connect ac power
to the sensor or
to terminals 1 and 2 of the transmitter
,
or replacement of the electronics board will
be necessary.
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......