![Rosemount 8712 Reference Manual Download Page 115](http://html1.mh-extra.com/html/rosemount/8712/8712_reference-manual_1487460115.webp)
Reference Manual
00809-0100-4664, Rev BA
January 2010
Rosemount 8712
www.rosemount.com
Appendix A
Reference Data
Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . page A-1
Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . page A-6
Physical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . page A-8
Rosemount 8712E Ordering Information . . . . . . . . . . . . . page A-9
NOTE
Detailed information for all Rosemount Magnetic Flowmeter Products can be
found in the latest revision of the 8700 Series Product Data Sheet
(p/n 00813-0100-4727).
FUNCTIONAL
SPECIFICATIONS
Sensor Compatibility
Compatible with Rosemount 8705, 8711, 8721, and 570TM sensors.
Compatible with Rosemount 8707 sensor with D2 Dual calibration option.
Compatible with AC and DC powered sensors of other manufacturers.
Sensor Coil Resistance
350
maximum
Transmitter Coil Drive Current
500 mA
Flow Rate Range
Capable of processing signals from fluids that are traveling between 0.01 and
39 ft/s (0 to 12 m/s) for both forward and reverse flow in all sensor sizes. Full
scale continuously adjustable between –39 and 39 ft/s (–12 to 12 m/s).
Conductivity Limits
Process liquid must have a conductivity of 5 microsiemens/cm (5
micromhos/cm) or greater for Rosemount 8712E. Excludes the effect of
interconnecting cable length in remote mount transmitter installations.
Power Supply
90-250 V AC, 50–60 Hz or 12–42 V DC
Summary of Contents for 8712
Page 2: ......
Page 4: ......
Page 26: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 2 16 ...
Page 84: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 4 46 ...
Page 102: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 5 18 ...
Page 114: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 6 12 ...
Page 154: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 D 6 ...
Page 194: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 E 40 ...
Page 208: ...Reference Manual 00809 0100 4664 Rev BA January 2010 Rosemount 8712 F 14 ...
Page 211: ......