Integer Scaling:
•
Scaling Method
: Integer scaling allows the host system to view
process variables as integers rather than floating point values. Integer
scaling methods are available per Table 4-4.
Table 4-4. Integer Scaling Methods
Entered Endpoints
Entered Endpoints
assigns a low and high integer that corresponds to a low
and high process reading and assumes a linear relation for values
in-between. Integer values must be between 0 and 65534. For more
information, see section 5.3.1.1 in the
Modbus Protocol Guide
located in
chapter 3 of the manual.
Integer Scaling Method
Description
Disabled
This is the default setting. Only floating point values will be
available when integer scaling is disabled.
Entered Endpoints
Allows you to define two endpoints for scaling each process
variable.
Entered Scale (slope) Factor &
Offset
Allows you to define the scale (slope) factor and offset for
scaling each process variable.
Calculated Scare (slope)
Factor & Offset
Allows you to have the User Interface Software calculate the
scale (slope) and offset for each process variable.