Specifications and Reference Data
September 2017
Reference Manual
00809-0100-4803, Rev GA
Specifications and Reference Data
138
A.3 Ordering information
A.3.1 Rosemount 3051S MultiVariable Transmitter
Table A-6. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (
★
) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Rosemount
model
Transmitter type
3051SMV
Scalable MultiVariable Transmitter
Performance class
Rosemount 3051SMV multivariable SuperModule, measurement types 1 and 2
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 12-year limited warranty
★
5
Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 15-year stability
★
Rosemount 3051SMV single variable SuperModule, measurement types 3 and 4
1
(2)
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty
★
2
Classic: 0.055% span DP accuracy, 100:1 rangedown, 5-year stability
★
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty
★
Multivariable type
M
Multivariable measurement with fully compensated mass and energy flow
★
P
Multivariable measurement with direct process variable output
★
Measurement type
1
Differential pressure, static pressure, and temperature
★
2
Differential pressure and static pressure
★
3
Differential pressure and temperature
★
4
Differential pressure
★
Differential pressure range
–3 to 3 inH
2
O (–7,47 to 7,47 mbar)
★
1
–25 to 25 inH
2
O (–62,2 to 62,2 mbar)
★
2
–250 to 250 inH
2
O (–623 to 623 mbar)
★
3
–1000 to 1000 inH
2
O (–2,5 to 2,5 bar)
★
4
–300 to 300 psi (–20,7 to 20,7 bar)
★
5
–2000 to 2000 psi (–137,9 to 137,9 bar)
★
Static pressure type
N
(4)
None
★
A
Absolute
★
G
Gage
★
Static pressure range
Absolute
Gage
N
None
N/A
N/A
★
3
Range 3
0.5 to 800 psia (0,03 to 55,2 bar)
–14.2 to 800 psig (–0,98 to 55,2 bar)
★
4
(5)
Range 4
0.5 to 3626 psia (0,03 to 250 bar)
–14.2 to 3626 psig (–0,98 to 250 bar)
★
Temperature input
N
(6)
None
★
R
(7)
RTD input (type Pt 100, –328 to 1562 °F [–200 to 850 °C])
★