4.6.2
Housing assembly including feature board electronics
Field device labels
The SuperModule label reflects the replacement model code for reordering a complete transmitter,
including both the SuperModule assembly and Plantweb
™
housing. The Rosemount 3051SMV model
code stamped on the Plantweb housing nameplate can be used to reorder the Plantweb housing
assembly.
Upgrading feature board electronics
The Rosemount 3051SMV allows feature board electronics upgrades. Different feature board electronics
assemblies provide new functionality and are easily interchanged for upgrade. When replacing or
upgrading the feature board electronics, use the
“Rosemount 300SMV housing kit” on page 144
which
also includes the appropriate Plantweb housing.
Upgrading or replacing the housing assembly including feature board
electronics
Remove the feature board
The Rosemount 3051SMV feature board is located opposite the field terminal side in the Plantweb
housing. To remove the feature board, perform the following procedure:
1. Remove the housing cover opposite the field terminal side.
2. Remove the LCD display, if applicable. To do this, hold in the two clips and pull outward. This will
provide better access to the two screws located on the feature board.
3. Loosen the two captive screws located on the feature board.
4. Pull out the feature board to expose and locate the SuperModule connector, see
5. Press the locking tabs and pull the SuperModule connector upwards (avoid pulling wires). Housing
rotation may be required to access locking tabs. See
for more
information.
Figure 4-9. SuperModule Connector View
A. Feature board
B. SuperModule connector
A