3-23
13
Connect the PANEL CABLE to the PANEL BOARD and
fix the PANEL COVER.
PANEL COVER
14
[MENU] key
[ ], [ ], [ ] + POWER ON
MENU
SERVICE MENU
Perform the SERVO LOCK CHECK.
After turning on the main power, turn on the sub power
while pressing the Left, Right and Down keys to enter
the SERVICE MODE.
15
16
[ ]
SERVICE MENU
SERVO LOCK
SERVO LOCK
S: 3
[ENTER]
SERVO LOCK
S: 1688
SERVO LOCK
S:* 1688
In [SERVO LOCK] menu, select [S].
Move the head carriage left and right by hand and
make sure the value on the LCD changes depending on
the head position.
Press the [ENTER] key to excite the MOTOR.
Make sure the MOTOR is locked and the value on the
LCD doesn't change.