4-49
4
8
Select [200gf] under [FORCE ADJUST] menu.
Press the [TEST CUT] key and move the TOOL down.
9
10
Pull up the Handle part of the TOOL HOLDER with the
TENSION GAUGE (ST-002) and measure the pressure
when the pen tip leaves the BED.
Adjust the parameter in the [200gf] menu with [ ] and
[ ] keys so that the pressure will be 195 ~ 205gf (1.9N
~ 2.0N).
Press the [ENTER] key to save the settings.
Enter [30gf] menu under [FORCE ADJUST] menu for
checking again.
Press the [TEST CUT] key and move the TOOL down.
ST-013
TOOL HOLDER
ST-013
TOOL HOLDER
Pull up the Handle part of the TOOL HOLDER with the
DIAL GAUGE (ST-013) and measure the pressure
when the pen tip leaves the BED.
Adjust the parameter in the [30gf] menu with [
] and
[
] keys so that the pressure will be 25 ~ 35gf(0.25N ~
0.35N).
Press the [ENTER] key to save the settings.
[ENTER]
30gf
17 16
[ ] [ ]
11
[TEST CUT]
200gf
56 57
SERVICE MENU
FORCE ADJUST
FORCE ADJUST
200gf
[ENTER]
200gf
56 57
[ ] [ ]
[TEST CUT]
30gf
17 16
SERVICE MENU
FORCE ADJUST
FORCE ADJUST
30gf