3-12
5
6
7
8
[ ]
[ ] [ ]
[ENTER]
SERVICE MENU
CAP&WIPER CTRL
CAP&WIPER CTRL
CAP
CAP
UP
Remove the PUMP COVER.
Select [CAP&WIPER CTRL] > [CAP] > [UP], and press
the [ENTER] key. The capping unit moves up. Press
the [ENTER] key 3 times, because the capping unit
moves up in 3 steps.
Turn off the SUB POWER SW, and then turn off the
MAIN POWER SW.
MAIN POWER SW
Disconnect the tube(Black) of the CAP TOP from the
tube(White) of the PUMP.
Keep the JOINT TUBE for connecting the tube of the
new CAP TOP.
JOINT TUBE
PUMP COVER