4-30
4
OK
OK
NG
NG
Cap the HEADs by moving the CAPPING UNIT with
[ ] and [ ] keys.
4
6
5
Unlock the carriage, and move the carriage out of the
CAPPING UNIT leftward by hand.
Make sure the HEADs are capped correctly.
If the WHITE GUIDEs of the CAPPING UNIT come
inside from the BLACK GUIDEs of the HEAD
CARRIAGE at either side, the capping position is not
OK. Proceed to the next step.
If the capping position is OK, press [ENTER] and
proceed to 12 .
WHITE
GUIDE
BLACK
GUIDE
PUMP COVER
Remove the PUMP COVER.