Manual
Double Sheet Detector R1000 series UDK20
B0048991 / Rev. 1.3
Technical data
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
11
2
Technical data
Pos: 10 /Doppelblech/Geräte/UDK20/2 Technische Daten/Gerätedaten UDK20 @ 1\mod_1306408099312_501.doc @ 9215 @ 2 @ 1
2.1
Technical data control unit UDK20
Operating voltage:
24 VDC, +6 V / -2 V
Power consumption:
60 W (operation: <60 W, in idle: <10 W)
Switch on current:
10 Amps for 1 ms
External fuse:
5 Amps medium time lag
Weight:
approx. 1.5 kg (3.30 lbs)
Ambient temperature:
0 - 50 °C (30 - 122° F)
Wall mount enclosure:
Protection category:
IP65
Dimensions without screw fittings:
approx. 205 x 140 x 80 mm (L x W x H)
approx. 8 x 5.5 x 3.15 inch (L x W x H)
Dimensions with screw fittings:
approx. 205 x 220 x 80 mm (L x W x H)
approx. 8 x 8.66 x 3.15 inch (L x W x H)
Front panel enclosure:
Protection category:
IP40 (inside)
IP65 (front cover)
Dimensions:
approx. 180 × 180 × 70 mm (L x W x H)
approx. 7.1 × 7.1 × 3 inch (L x W x H)
Additional characteristics:
• 255 parameter sets memory
• Programming via pushbuttons
• 9 potential free optocoupler inputs 24 VDC with joint common
Specification:
min. switching voltage HIGH:
13 VDC
max. switching voltage HIGH:
30 VDC
min. switching voltage LOW:
0 VDC
max. switching voltage LOW:
8 VDC
• 4 potential free outputs with positive external supply
Specification
relay version:
Switching outputs
Dry relay opening contacts
max. switching voltage:
250 VAC
max. switching current:
1 A
max. switching power:
240 W / 200 VA
Specification
opto coupler version:
Switching outputs
unwired Emitter and Collector
max. switching voltage:
50 VDC
max. switching current:
150 mA
max. switching power:
100 mW
Attention
In case of inductive load a coil protection diode should be used.
Otherwise the signal output could be destroyed by the excess voltage
generated by switching the inductive load off.