Manual
Double Sheet Detector R1000 series UDK20
Start-up
B0048991 / Rev. 1.3
90
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
7.7
System parameters
Note
The selected system configuration should be documented in the form
“System configuration“ in the chapter 13.2. This information is required in
case a system needs to be exchanged.
The general adjustments are specified in the system parameters. For accessing, select the “system
parameter configuration“ mode and confirm with
ENTER
.
System parameter 1:
Setting the dialogue language.
Fig. 50: Selecting the dialogue language
System parameter 2:
Specifying the type of sensor.
Fig. 51: Specifying the type of sensor
Currently only the type of sensor PW42A is selectable.
System parameter 3:
Specifying the number of connected sensors.
Fig. 52: Specifying the number of sensors
Possible choices:
•
for 2PW-unit: 1 / 2 sensors
•
for SSB: 1 / 2 / 3 / 4 sensors
Attention
If a particular configuration is changed, all stored program
parameters are deleted. Then for all types of material the nominal
thicknesses must be entered again and the Teach-In executed.
system param. 1
language:english
system param. 3
number sensors:2
system param. 2
sensor type:PW42