Manual
Double Sheet Detector R1000 series UDK20
Technical data
B0048991 / Rev. 1.3
20
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
2.6.2 Sensor cable extensions
A sensor cable extension can be relatively easy made. For this a SCPWS-GG or SCPWS-GW
cable is always needed.
2.6.3 Cable for Sensor-Switch-Box SSBUDK10
The cable SVCPWS-SSBUDK10 is used for connecting the control unit to the Sensor Switch Box.
The following pin configuration and dimensions apply:
to Sensor-Switch-Box
to unit
Cable socket
Cable plug
2
3
5
4
51
22
22
2
3
5
4
1
white
2
green
3
brown
4
yellow
5
grey
Enclosure
blank (Shield)
1
white
2
green
3
brown
4
yellow
5
grey
Enclosure
blank (Shield)
to Sensor-Switch-Box
to unit
Cable socket
Cable plug
1
2
3
4
5
grey
white
brown
green
yellow
SS
BU
DK
10
1
2
3
5
4
1
2
3
5
4
1
white
2
green
3
brown
4
yellow
5
grey
Enclosure blank (Shield)
Cable type for SSBUDK10 (order data):
•
SVCPWS-SSBUDK10
The standard length is 5 meter.
Note
For the connection of the SSBUDK10 to the sensor PW42AGS the
SCPWSGG or SCPWS-GW are used.
Pos: 16 /Komponenten allgemein/Leerseite @ 0\mod_1165223317234_501.doc @ 2343 @ @ 1
Pos: 17 /Kapitelübersicht/03. Systembeschreibung @ 0\mod_1121421150062_501.doc @ 507 @ 1 @ 1