The data for 2 sensors apply in the so-called sequencer mode.
Standard working range
Single sheet thickness
(Nominal thickness) [mm]
40
50
60
70
80
90
100
110
120
130
140
150
160
170
2 Sensors
1 Sensor
PW42AGS
150 %
120 %
0,5
1,0
1,5
2,0
2,5
0
3,0
3,5
4,0
Fig. 3: System reaction time P42AGS
Double sheet thresholds above 120% reduce the performance of the system with regard to air gaps
between the sheets and increase the systems reaction time according to the diagram.
Air gaps influence the performance negatively because air has - in contrast to steel - a high
resistance to the magnetic flux. Therefore, air gaps reduce the performance of the system
considerably (see chapter “3.1 Measuring principle and conditions influencing measurement
accuray“).
For reliable double sheet monitoring there should be no air gap between sheet and sensor and also
between the sheets. The most reliable double sheet recognition results, if no air gaps exists. These
aspects should be specifically observed when mounting the sensors.
The influence of air gaps are described in the following diagrams.