Manual
Double Sheet Detector R1000 series UDK20
Fault messages, causes and remedies
B0048991 / Rev. 1.3
102
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
9.1
Fault messages of the Sensor-Switch-Box
If the Sensor-Switch-Box was configured though none is attached to the system, then the system
emits a fault message. In order to reconfigure the equipment to the correct adjustment “no Sensor
Switch Box“, the unit must be switched off and on.
The following message is displayed:
Fig. 78: System does not recognize a Sensor-Switch-Box
After pressing the MENU key the following message is displayed:
Fig. 79: Selection, if the Sensor-Switch-Box is to be operated
Adjustment for operating the Sensor Switch Box:
•
yes: The equipment should continue operating with a Sensor Switch Box.
The fault is cleared. If the fault condition is not eliminated, then the fault message appears
again.
•
no = CLR Param.: The equipment has to be reconfigured to operate without a Sensor Switch
Box. All program parameters are deleted.
Attention
The deletion of the programs parameter cannot be undone.
The arrow keys allow the change between “yes“ and “no“. Confirm the selection with the ENTER
key.
UDK20+switchbox?
yes
no switchbox
or defective