background image

WIRELESS ALARM SYSTEM

WIRELESS ALARM SYSTEM

I n s t a l l a t i o n   a n d   u s e   i n s t r u c t i o n s

Summary of Contents for HOME SHIELD

Page 1: ...WIRELESS ALARM SYSTEM WIRELESS ALARM SYSTEM I n s t a l l a t i o n a n d u s e i n s t r u c t i o n s...

Page 2: ...prepared during production to operate together from the very first enablement without the need for additional programming devices purchased separately must be integrated in the system by programming...

Page 3: ...kit devices p 4 Transmission by double band radio p 6 The system s surveillance p 6 Operation according to areas p 7 Installing the system devices p 8 H4 Alarm Control Unit with telephone transmitter...

Page 4: ...to listen to the noises in the room where it is installed It can be remotely enabled or disabled and also indicates the system s current status and the internal temperature 4 key remote control For to...

Page 5: ...he external temperature if an outdoor siren is connected to the system It also enables the system to be customised Customised configuration We recommend the following to facilitate system start up in...

Page 6: ...rmanently supervised to ensure optimal operation each device regularly sends a radio message to the control unit to confirm its operational status to the control unit When the control unit no longer r...

Page 7: ...detectors will be included With a garage Specify an area for the garage to simultaneously protect both house and garage there is no need to create an area for the dwelling only total protection can b...

Page 8: ...n signal Peripheral units fault Telephone line fault Discharged batteries Cable route Securing screws Self protection route 1 50 m Alarm ON Alarm OFF Maintenance Program mode 2 secs Alarm memory store...

Page 9: ...formation Status Closed contact alarm system enabled Open contact alarm system disabled Alarm output of alarm in progress open collector The output which is normally floating is earth connected when t...

Page 10: ...ecifications The spacers supplied with the detector make it possible to adjust the position of the magnetic cover Securing Magnetic enclosure Open the cover Secure the base observing the positioning p...

Page 11: ...nd closing movement ON 3 1 2 BeeP ON Immediate alarm ON Delayed alarm Immediate alarm Immediate alarm In case of detection the alarm is tripped immediately Dela Delay yed alarm ed alarm The alarm is t...

Page 12: ...a convector Installation at a height of 2 3 m off the floor 1 2 Parts to eliminate Secured on an articulated joint 1 Secure the articulated joint 2 Secure the sensor on the articulated joint Wall Sec...

Page 13: ...gnalled by a beep OFF OFF OFF OFF ON Immediate alarm Delayed alarm Immediate alarm Immediate alarm In case of detection the alarm is tripped immediately Dela Delay yed alarm ed alarm The alarm is trip...

Page 14: ...and remove the front cover Secure the keypad support observing the positioning precautions screws and expansion plugs supplied Start up Remove the plastic strip from the batteries Close the enclosure...

Page 15: ...and then press the configuration access push button When INSTALLATION is shown press OK and open the control unit compartment From this moment on the control unit is in MAINTENANCE PROGRAM mode Items...

Page 16: ...ou should hear a beep from the control unit press the OFF key of the slave remote control for about one second press the OFF key again for about 1 second you should hear two beeps from the control uni...

Page 17: ...unit in MAINTENANCE PROGRAM mode using a remote control The control unit must be in alarm OFF mode Press push buttons 1 and 2 of a Master remote control and release them when the indicator light flas...

Page 18: ...re inputting the access code When input for the first time the code is 1234 Press the key and then type in the first 2 digits of the access code with push buttons Press again and type in the last 2 d...

Page 19: ...access code for displaying the system s status press the configuration access push button Select the LEARNING menu and then confirm The countdown begins from 69 to 0 the keypad and the control unit e...

Page 20: ...the choice of name with and then assign a number to it if no preset name is correct select OTHER and type in the desired name letter by letter 7 characters maximum The control unit will confirm the r...

Page 21: ...ss the test push button of every device to be associated with the selected area not including technical detectors and control devices The control unit sounds a BEEP for every selected device after you...

Page 22: ...ogress System sabotage alarm Discharged batteries Peripheral units fault Telephone line fault Passage open signal Alarm ON Alarm OFF Maintenance Program mode 2 secs Alarm memory stored In progress Sys...

Page 23: ...modify the telephone numbers to be called press to modify the voice message press to modify the access code press to modify the time press to modify the date press 1 2 3 4 5 Alarm ON Alarm OFF Mainte...

Page 24: ...1 2 4 3 For example 02 99 73 The third number to call is 02 99 73 To modify it press or press to return to the previous menu To modify one of the telephone numbers to be called press or or or or pres...

Page 25: ...ime or press to return to the previous menu The time is 11 and 27 minutes Type in the 4 digits of the new time or press to return to the previous menu Press the asterisk to return to the previous menu...

Page 26: ...a t u r a t i o n t e l e p h o n e l i n e m o n o b i Standard battery consumption Acoustic signal Saturation enabled Customising the system Customising 26 Control unit internal siren In case of an...

Page 27: ...secs Passage open signal Peripheral units fault Telephone line fault Discharged batteries System sabotage alarm Alarm memory stored In progress Maintenance Program mode Alarm ON Alarm OFF Close the co...

Page 28: ...TE DEVICES menu and confirm select the device to be eliminated by pressing keys and or by directly pressing the TEST push button of the device to be eliminated not including remote controls the identi...

Page 29: ...nit sounds a first long BEEP continue pressing the push button until you hear the second BEEP the 5 indicator lights flash simultaneously Deleting all devices from an area To ensure that the sensors a...

Page 30: ...in the area involved General information BeeP BeeP Alarm disabled Alarm ON Alarm OFF Maintenance Program mode 2 secs Alarm memory stored In progress System sabotage alarm Discharged batteries Peripher...

Page 31: ...arm is enabled Using push buttons and select the mode Confirm by pressing Disabling under threat This function is used to make possible aggressor believe that you are typing in the real keypad access...

Page 32: ...lting alarm events OK C INFO OK C INFO OK INFO INFO INFO INFO INFO INFO INFO INFO Type in the access code The problem sign appears on the display it means that a given event has occurred Press the key...

Page 33: ...abled On 17 June 2004 at 12 37 hours intrusion alarm bedroom 2 Indoor temperature is 19 C Main menu To delete the alarm message press Alarm enabled no signalling Indoor temperature is 19 C Enabling th...

Page 34: ...is 19 C Main menu to enable the alarm press to listen press to speak press to customise the telephone transmitter press to hang up press twice 1 2 3 4 Alarm ON Alarm OFF Maintenance Program mode 2 sec...

Page 35: ...e alarm is enabled or disabled by some beeps and on the control keypad Technical alarm optional or emergency call emergency call panic button the telephone transmitter is enabled and the control unit...

Page 36: ...nfirm reception of call OBLIGATORY to stop the control unit calling the other numbers How a call occurs In the event of an alarm due to intrusion or sabotage the telephone transmitter calls the progra...

Page 37: ...ine fault Discharged batteries System sabotage alarm Alarm memory stored In progress Maintenance Program mode Alarm ON Alarm OFF Put the control unit in MAINTENANCE PROGRAM mode Surveillance must be d...

Page 38: ...ening detector Power supply two 1 5 volt alkaline batteries type LR203 or AAA Time range 3 years under normal use conditions Radio range from 200 to 300 m according to environment Radio frequency band...

Page 39: ...hen the test push button is pressed The indicator light of the remote control does not light up when the key is pressed The control keypad display is completely OFF The control keypad does not sound a...

Page 40: ...ccess code The keypad is not activating the control unit Check if the keypad is actually recognised by the control unit Check if communication to the control unit is effective and if necessary move th...

Page 41: ...ber 2000 It is declared that the essential radio tests were performed The CE mark is affixed to the product Year when CE mark was affixed 2003 Constructor s CE Declaration Alarm control unit N 02 035_...