Installing the system devices
Choice of location
The control unit should be installed:
- in a flat surface, with sufficient space around to open
the battery compartment,
- in the centre of the house and high up (for better radio
range),
- in an obstacle-free place for excellent sound diffusion
of the integrated siren,
- in a place difficult to reach by an intruder, but
accessible for the user,
- in a place protected by a movement detector.
Securing
Install the control unit near a wall-fitted telephone socket,
in a place permitting effective listening of the rooms.
Open the battery compartment with the supplied key.
Remove the batteries and the plastic strip.
Loosen the two securing screws and remove the front
cover.
Drill the holes in the specified securing points and
secure the support on the wall in the four indicated
points.
Re-position the cover of the control unit on its wall
support and secure the screw.
Start-up
Fit the batteries respecting the indicated polarity.
The control unit is installed.
not recommended
not recommended
recommended
recommended
AP
EFF
TEST
+
+
+
-
-
+
-
2 sec.
Passage open signal
Peripheral units fault /
Telephone line fault
Discharged batteries
Cable
route
Securing
screws
Self-protection route
1.50 m
Alarm ON / Alarm OFF
Maintenance Program mode
2 secs.
Alarm memory-stored / In progress
System sabotage alarm
Discharged batteries
Peripheral units fault /
Telephone line fault
Passage open signal
A
B
C
AP
SUPTEST
2
3
2 secs.
Passage open signal
Peripheral units fault /
Telephone line fault
Discharged batteries
System sabotage alarm
Alarm memory-stored / In progress
Maintenance Program mode
Alarm ON / Alarm OFF
H4 Alarm Control Unit with
telephone transmitter and siren
Impor
Impor
tant:
tant:
Do not close the control unit compartment before you have
installed the system’s other elements (detectors, sirens…).
Attention:
Attention:
To ensure that alarm messages are correctly sent,
modify the system as described below:
connect the RJ11 plug, on the short side of the
supplied cable, to the entry-point of the telephone line,
connect the RJ11 plug, on the long side of the
supplied cable, to the socket of the control unit,
connect the telephones to the RJ11 socket on the
supplied cable.
If this modification is not carried out, the message
could be prevented from being sent, by lifting up a
receiver before the transmitter begins the sending
procedure.
Installation
A
B
C