When Moving the Machine
When moving the machine, secure the UV irradiation outlet shutter, and tape the front cover down.
Required items
Retainer (large): 1
Retainer (small): 2
NOTE
Use the original retainers that were supplied when the product was delivered. If the original retainers are no longer available, use an alternative that is capable of
holding the UV irradiation outlet shutter in place. If the retainers are not attached or the cover is not taped down, the machine may be damaged.
1.
Place the large retainer on top of the UV irradiation outlet shutter.
Fix the shutter in place so that it does not open. Insert the large retainer into
the center of the recess in the irradiation outlet.
If you are not using the original retainers, use an alternative, taking care to
ensure that the shutter does not open.
Retainer (large)
Shutter
2.
Place the two small retainers on either side of the large retainer, and
gently fix the edge of each small retainer in place with the liquid
material vat stopper.
Loosen the liquid material vat retaining screws so that the edge of each small
retainer is just held in place.
Retainer (small)
Retainer (small)